dB from 63Hz to 8KHz:
|
Enter the levels in dB per octave-band.
|
Calculation:
|
Launch the global level calculation.
|
Initialization:
|
Configurated at level of 99dB in the bands 125, 250, 500, 1KHz, 2KHz and 4KHz.Configurated at level of 0dB on the bands 63KHz and 8KHz.The weighted total is nearly 105dB.
|
Weighting A:
|
Result in dB of global weighting level A.
|
Weighting C:
|
Result in dB of global weighting level C.
|
Weighting Z:
|
Result in dB of global weighting level Z.
|
Level per Octave:
|
The levels per octave-bands are displayed, taking into account the weighting, A in yellow, C in blue, Z in green.
|
Global Level:
|
The global level is displayed for the weighting, A in yellow, C in blue, Z in green.
|
Example:
|
We can notice the very low influence of the 63Hz and 125Hz bands on the global in A against the global C and Z. The initialization values give A: 105.3dB C: 106.6dB Z: 106.8dB.
-
If we add 10dB at level 15Hz => 99 + 10 = 109dB
The levels come to A: 105.47dB C: 110.56 Z: 110.76
-
If we add in addition 120dB to 63Hz => 0 + 120 = 120dB.
The levels come to A: 105.76 C: 119.76 Z: 120.49.
We see that the global A virtually didn’t move against C and Z although we switched from 99 to 109dB for the 125Hz and from 0dB to 120dB for the 63Hz.
Therefore we note that only the action per octave-band can solve the emergence problems ( situated virtually always at the bottom of the spectrum) eventually the action in global C but of course not the action in weighting A.
|